検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 5 件中 1件目~5件目を表示
  • 1

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

Development of a DDA+PGA-combined non-destructive active interrogation system in "Active-N"

古高 和禎; 大図 章; 藤 暢輔

Nuclear Engineering and Technology, 55(11), p.4002 - 4018, 2023/11

 被引用回数:0 パーセンタイル:0.01(Nuclear Science & Technology)

An integrated neutron interrogation system has been developed for non-destructive assay of highly radioactive special nuclear materials, to accumulate knowledge of the method through developing and using it. The system combines a differential die-away (DDA) measurement system for the quantification of nuclear materials and a prompt gamma-ray analysis (PGA) system for the detection of neutron poisons which disturb the DDA measurements; a common D-T neutron generator is used. A special care has been taken for the selection of materials to reduce the background gamma rays produced by the interrogation neutrons. A series of measurements were performed to test the basic performance of the system. The results show that the DDA system can quantify plutonium of as small as 20~mg and it is not affected by intense neutron background up to 4.2~TBq and gamma ray of 2.2~TBq. As a result of the designing of the combined system as a whole, the gamma-ray background counting rate at the PGA detector was reduced down to $$3.9times10^{3}$$ s$$^{-1}$$ even with the use of the D-T neutron generator. The test measurements show that the PGA system is capable of detecting less than 1~g of boron compound and about 100~g of gadolinium compound in~30 min. This research was implemented under the subsidy for nuclear security promotion of MEXT.

論文

Development of correction method for sample density effect on PGA

前田 亮; 瀬川 麻里子; 藤 暢輔; 遠藤 駿典; 中村 詔司; 木村 敦

Journal of Radioanalytical and Nuclear Chemistry, 332(8), p.2995 - 2999, 2023/08

 被引用回数:0 パーセンタイル:0.01(Chemistry, Analytical)

The accuracy of the prompt $$gamma$$-ray analysis is known to degrade for the samples containing neutron-scattering materials, such as hydrogen, depending on its content. Recently, we discovered that the density of the scattering materials also affects the accuracy. In this paper, we developed a correction method for the effect of the sample densities. The developed correction method is straightforward and applicable to samples with unknown densities. The simulation and experiments verified the performance of the correction method. The results confirmed that the correction method could reduce the uncertainty due to sample density from 47% to approximately 1%.

論文

Techniques of neutron resonance capture analysis and prompt $$gamma$$-ray analysis for active neutron NDA

小泉 光生; 土屋 晴文; 北谷 文人; 呉田 昌俊; 瀬谷 道夫; 原田 秀郎; Heyse, J.*; Kopecky, S.*; Mondelaers, W.*; Paradela, C.*; et al.

Proceedings of 37th ESARDA Annual Meeting (Internet), p.852 - 858, 2015/08

Active NDA techniques will draw out more information on the sample objects, in comparison with passive NDA techniques. Elementary particles (such as photons and neutrons) are used to induce nuclear reactions in the sample objects. The materials in the objects are deduced from the measured particles coming out of them. A new development program of active neutron NDA technologies has been started for detection/measurement of nuclear materials using a pulsed neutron source for nuclear security and nuclear non-proliferation; this project includes the basic technological development of NRTA, NRCA/PGA, neutron differential die-away (DDA) and a Delayed Gamma-ray (DG) technique. A system of active neutron NDA has been proposed. In this presentation, we review the methods and techniques on NRCA and PGA, which will be utilized for identifying materials in the objects in active neutron NDA.

論文

The Prediction of Boron concentrations in blood for patients of boron neutron capture therapy, 2

柴田 靖*; 松村 明*; 山本 哲哉*; 阿久津 博義*; 安田 貢*; 中井 啓*; 能勢 忠男*; 山本 和喜; 熊田 博明; 堀 直彦; et al.

Research and Development in Neutron Capture Therapy, p.1055 - 1060, 2002/09

腫瘍摘出する初期開頭手術時に患者にホウ素薬剤(BSH)を少量投与し、得られた生物学的薬剤分布データを用いて、医療照射当日の血液ホウ素濃度の予測について予備調査を行った。悪性グリア腫瘍の患者9名は1995から2001年の間に日本原子力研究所においてホウ素中性子補足療法を受けた者である。その内7名については、腫瘍摘出の前にBSH1gを注入し、即発$$gamma$$線分析装置(PGA)を用いてホウ素濃度の測定を行った。BNCT照射12時間前にBSHを100mg/kgの投与量を患者に注入し、ホウ素濃度を再び決定した。その結果、ホウ素の生物学的薬剤分布データは2相指数曲線の薬物動態分布を示した。もし、注入後から6時間又は9時間の医療照射直前のホウ素濃度が予測値に対して95%予測信頼区間にあれば、2相指数曲線フィットからの直接予測は照射時間内の血液ホウ素濃度の誤差を6%程度に抑えることができる。

論文

Prompt gamma-ray analysis using cold and thermal guided neutron beams at JAERI

米澤 仲四郎; 松江 秀明; 間柄 正明; 星 三千男; 澤幡 浩之*; 伊藤 泰男*

Proc. of 9th Int. Symp. on Capture Gamma-ray Spectroscopy and Related Topics, 0, p.705 - 712, 1997/00

JRR-3Mの冷及び熱中性子ガイドビームを使用した恒久的な即発ガンマ線分析装置を製作した。装置は、即発$$gamma$$線分析(PGA)で重要な低$$gamma$$線バックグラウンドになるように設計されており、このため1)中性子のしゃへい材としてフッ化リチウムタイルの使用、2)He雰囲気中での照射・測定、3)Ge-13GD検出器によるコンプトンバックグラウンドの低減化等の対策がとられている。$$gamma$$線スペクトロメーターは、コンプトンサプレッション、ペアー及びシングルの3モードスペクトルを同時に測定することができる。本装置は、低$$gamma$$線バックグラウンド化により、従来の装置より分析感度及び検出限界が勝れていることが明らかにされた。本装置によりホウ素及び多元素定量法の検討を行い、各種環境試料分析に適用した。さらに、本装置による同位体分析、考古学、地質、農業、材料科学、医学等の各種分野試料の分析に関する研究も紹介する。

5 件中 1件目~5件目を表示
  • 1